Invalid Element. Unable to solve rule please correct element construction.
We would like to get some more information when this message appears, e.g. full explanation about what is wrong. When we are breaking a rule ORD should keep history and detailed explanation about what is broken, get a better history and presentati...
Please include a tool similar to the Drainage Structure Analyzer from Inroads Storm and Sanitary. This tool is very useful for quick sizing without having to set up a model, especially with culverts and channels.
Allow "Save Settings" to save your preferred default settings in the Feature Definition Tool Bar
Many users prefer different settings to be selected by default in the Feature Definition Tool Bar. Currently, "Persist Snaps and Rule" is always ON by default when opening a file but nothing else. Even if you turn this off, or activate another set...
When creating centerline geometry you may need it to be parallel to outside boundaries like Right of Way. It would be convenient to be able to select that snap and use it like it works for MicroStation lines.
Label all the points in a superelevation section with Civil Labeler
Superelevation is a tabular note that goes on the general info sheet with the super elevation diagram, so we usually just fill out the info in that tabular note. Designers just blow up the tabular note to add lines and make it work per project. If...
Create Template Geometry - Option to create 2D Elements from points located below top surface
Currently only template points located on top surface can produce 2d linear elements. This also only seems possible, when the components they belong to, are not ‘Excluded From Top/Bottom Mesh’ (option in Component properties dialog) and the ‘Creat...
When working in Projectwise projects, the "Load Temporary Library" ONLY allows us to select files from the server. It would be great if it would allow us to choose files from ProjectWise to temporarily load too.
When starting a DU, OpenRoads creates a whole DU project inside the file and brings a lot of hidroly/hidraulic properties with it. That's fine if the goal is to run an analysis. But what if I just want to model a whole network and never run it? Di...
Creating virtual signaling elements in ORD with the tool Equipment
Curently is not possible to represent signalling virtual elements that are related to an area extent and depend from 2 elements or Pk start/end. For example a neutral section, or emergency stop area, or track circuit.