The prompt for compressing the drainage database needs some work: It really should be removed. Salvaging anything marked for deletion but not compressed isn't really feasible in OpenRoads environment. Do not prompt me twice. It should be assumed t...
ORD SUDA - Single gradient property - False for stormwater and wastewater conduit
Hi, We were wondering if it would be possible to change the single gradient property function for stormwater and wastewater conduit.
"Single Gradient - This is always set to true for storm and sanitary conduits. For other types of conduit, it i...
For steel beams- When we create stiffeners and use them in cross frame definition, regardless of the method used, the stiffener tables when opened default to the first stiffener in the OBM library rather than the stiffener used in cross frame definition
Currently when we create a new stiffener and then when we create cross frames using those stiffeners, they don't show up when you open stiffener definition after creating cross frames (the first stiffener definition within the selection is shown)
Export pier or abutment templates to Functional Component
Often times a small edit is needed to make an existing abutment or pier template match project standards. It is tedious to create a Functional Component from scratch for small edits. It would be helpful to have a tool or button to export a templat...
over 1 year ago
in Modeling
0
Future consideration
Create multiple long sections/profiles in the same model space
When creating profiles/long sections for track vertical geometry, ORD creates an individual sheet view and model view for each sheet. This creates a large amount of work when trying to bulk annotate or export long sections for drafting. It would b...
I would like to make a suggestion on an improvement to template design for 3D Modeling in ORD. The Rollover values tool in superelevation template design is incredibly helpful, as it saves time by calculating the proper shoulder super rates accord...
Option to Edit the Loads Font on Leap Conc -> Sub -> Geo Tab
I would like the option to edit the font on the Leap Concrete, Substructure tab, Geometry Tab. This way the text displayed that shows the loads can be increased which can help when saving images for review and record keeping. Thanks
Allow Level Overrides to Work With Profiles Created From Named Boundaries
This may very well just be Another Bug, but Level Overrides do not seem to work with Profiles cut from named boundaries. When setting up the Profile View and displaying the different surface profiles that are desired, we can use level overrides to...
In PRT it was possible to snap a smart line to a specific chainage in plan by using the key-in 'SO=xxx'. In OpenRail the closest tool I can find is Civil Accudraw with station-offset toggled on, but I have found that often CivilAccudraw does not w...