Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Bentley Civil Product Ideas

Showing 1747 of 1747

Allow the Text Import Wizard to process Geopak Drainage survey source files without editing

In order to export drainage data, two items must be noted during the field collection. Each pipe must have a size and condition. These must be placed as the first characters in the description field separated by a space. If two different sizes are...
over 2 years ago in OpenRail Designer / OpenRoads Designer / OpenSite Designer / Survey 0 Future consideration

Allow Surface Template for Corridor Top/Bottom Meshes

It would be extremely powerful if Surface Templates could select and use Corridor Top or Bottom Meshes as their base surface. If these were ruled users could create irregular shaped pavement elements with ease. This is something currently very lab...
over 2 years ago in Modeling / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Transverse PT for shell element segmental box girder

Introduction of Transverse PT for shell element segmental box girder.
almost 2 years ago in OpenBridge Designer 0 Needs review

Remove the Volume Exception Stations from End Area Volumes Report

If we add the Volume Exception stations (Cross Section Named Boundaries) for which we don not want to generate the End Area Volumes, The generated report still reports the Stations with the 0 Volume and its area. Kindly add an option to remove the...
over 2 years ago in OpenRail Designer / OpenRoads Designer / OpenSite Designer / Reports 0 Future consideration

Annotation Group Definition Copied to Active File when Used

When labeling civil geometry (alignments for example), whichever annotation group that is utilized is copied from the DNGLIB and saved with the active DGN. This is only the case when the geometry being annotated is stored within the active DGN, no...
7 months ago in Drawing Production / OpenRail Designer / OpenRoads Designer / Workspace 0 Future consideration

Issues with Drainage Prompt to compress database

The prompt for compressing the drainage database needs some work: It really should be removed. Salvaging anything marked for deletion but not compressed isn't really feasible in OpenRoads environment. Do not prompt me twice. It should be assumed t...
7 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer 1 Future consideration

ORD SUDA - Single gradient property - False for stormwater and wastewater conduit

Hi, We were wondering if it would be possible to change the single gradient property function for stormwater and wastewater conduit. "Single Gradient - This is always set to true for storm and sanitary conduits. For other types of conduit, it i...
7 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer 2 Future consideration

Preview Sign Designs in ProjectWise

With the integration of ProjectWise, I would like to see if the preview window in the document properties can display a view of the sign design as it does with OpenRoads Designer and the last view.
about 1 year ago in OpenRoads SignCAD 0 Future consideration

Make Grips Visible and Useable on 4k displays

When using Grips for Structures and Pipes - the grip blends too much into the background color, and on a 4K screen is TINY. The pipe grip is annoying to select (it only appears when I select the centerline of the pipe) but when adjusting or swapin...
almost 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer / User Interface 1 Future consideration

Add minimum vertical clearance results to delta surface tool

After creating the delta surface, we could not determine the location of minimum vertical clearance. We tried the analyze surface tool and it showed us coordinates of the min/max locations. However, the locations were outside of the delta surface....
about 1 year ago in OpenBridge Modeler / OpenRoads Designer / Terrain 0 Future consideration