Drainage and Utilities

Showing 73

Drainage Structure Analyzer

Please include a tool similar to the Drainage Structure Analyzer from Inroads Storm and Sanitary. This tool is very useful for quick sizing without having to set up a model, especially with culverts and channels.
over 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Add ability to set default Engineering Libraries for all users

As it stands, I can make a new Engineering Library on a network drive to share with other users, but if I wanted to make that library the "default", I can't without having to make the change for each individual user.
about 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

ORD Drainage - Show actual Tc versus Tc Minimum

Many times a calculated Time of Concentration is less than the minimum used for Intensity. When this occurs in a system of drainage areas (catchments), it helps a designer AND a reviewer to see what the actual Time of Concentration is at a given p...
about 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Need ability to define variable wall thickness on conduits

For box shaped conduits, we need to be able to define top, bottom and side wall thicknesses independently. This allows modeling of box shapes which correspond to physical construction.
almost 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 1 Future consideration

Issues with Drainage Prompt to compress database

The prompt for compressing the drainage database needs some work: It really should be removed. Salvaging anything marked for deletion but not compressed isn't really feasible in OpenRoads environment. Do not prompt me twice. It should be assumed t...
5 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer 1 Future consideration

ORD SUDA - Single gradient property - False for stormwater and wastewater conduit

Hi, We were wondering if it would be possible to change the single gradient property function for stormwater and wastewater conduit. "Single Gradient - This is always set to true for storm and sanitary conduits. For other types of conduit, it i...
5 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer 2 Future consideration

Add Conduit To Existing Profile Run

It would be very helpful if there was a way to simply Add a Conduit to an existing Profile Run. For example, I have a storm network modeled and a bunch of drawings created by using a Profile Run, but now I needed to add another conduit at the end ...
5 months ago in Drainage and Utilities / Drawing Production / OpenRail Designer / OpenRoads Designer 0 Future consideration

Ablity to connect two nodes directly by flange

For the water supply project, in a situation where we have cast iron elements connected to the flange such as gate valves, hydrants, elbows, venturiers and plastic line pipes. There is no way to connect the two nodes directly through the flange. a...
over 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Utility Enhancements

Add the conduit table options similar to drainage for managing conduit sizes, materials, etc... Right now you have to input a conduit table for each utility type and can't import a table from utility to utility. Just need one set of tables to mana...
over 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer / Workspace 0 Future consideration

Openroads Drainage - HGL versus Headwater Analysis for Headwalls Inletting into a Storm Sewer System

Many times, a stream needs to be drained into a storm sewer system via a headwall. When this occurs, two analysis should be considered: The headwater at the headwall (the mechanics of the water getting into the pipe at the headwall). Generally KYT...
about 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration