Need bent plate connection plates for diaphragm and cross frames.
OBM does not currently allow for bent connection plates for diaphragms / cross frames. We need that ability to cover bridges skewed between 20 and 45 degrees.
The OBM development team has started to work on this enhancement. We are looking for some real world drawings to help clarify how the plates connect on either end. If you have any drawings please add them here or send via email to sri.kanneganti@bentley.com
Attached is how UDOT uses the bent connection plates.
NYSDOT has standard details that we typically follow for this. see dwg BD-SG2E sections C-C and D-D for skews over 20 degrees. https://www.dot.ny.gov/main/business-center/engineering/cadd-info/bridge-details-sheets-repostitory-usc/BD-SG_SET_USC-03-22.pdf
The OBM development team has started to work on this enhancement. We are looking for some real world drawings to help clarify how the plates connect on either end. If you have any drawings please add them here or send via email to sri.kanneganti@bentley.com
Thanks in advance for your help.