ORD Drainage - Show actual Tc versus Tc Minimum

Many times a calculated Time of Concentration is less than the minimum used for Intensity. When this occurs in a system of drainage areas (catchments), it helps a designer AND a reviewer to see what the actual Time of Concentration is at a given p...
over 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

SUDA - Spread Slope

Make it easier to manage longitudinal spread slope. It's nice to input the slope in the properties per node, but consider making it integrated to the gutters used during bypass flow drawing of gutters.
over 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Needs review

Include NR60 Mk2 turnout definition in OpenRail

NR60 Mk2 turnouts to be included by default in the standard OpenRail definitions.
about 2 years ago in Turnouts/Crossings 1 Future consideration

Static Item Type Expression values

Currently Item Types with Expressions update whenever properties are displayed. etc and are always "live" even via referencing, etc. This causes many issues where the original Excel lookup spreadsheet or Civil data is not present (when viewed in M...
about 2 years ago in Item Types / OpenBridge Designer / OpenRail Designer / OpenRoads Designer / OpenSite Designer 1 Future consideration

Ablity to connect two nodes directly by flange

For the water supply project, in a situation where we have cast iron elements connected to the flange such as gate valves, hydrants, elbows, venturiers and plastic line pipes. There is no way to connect the two nodes directly through the flange. a...
almost 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Geometry Connector: automatically use turnout radius when connecting an arc to a turnout

When using Geometry Connector to connect turnouts, it is often that we must extend the last arc of the turnout. Because the arc is in the turnout we cannot extend it. Instead, we must add an arc of same radius. It would be nice that in such situat...
4 months ago in Geometry / OpenRail Designer 0 Future consideration

Reverse slue sign convention

Ability to amend slue convention to be either right or left as positive slue to account for regional preferences/conventions
about 2 years ago in Annotation 0 Future consideration

CAD export settings

So, we have been told that exporting to DXF or DWG will not be implemented. Could we talk about bringing back the CAD export settings from the legacy version. I can open DGN files in several 3rd party software packages but need to turn off block t...
4 months ago in Import/Export / OpenRoads SignCAD 3 Future consideration

OpenBuildings Axis and Building organization in OpenSite

OpenSite should be closer to OpenBuildings than to OpenRoads. Site projects desingers most of the times are working close to architecutes, structure engineers and landscape designers. We miss the commun tools for those enviromments, like BUILDING ...
4 months ago in Workspace 0 Future consideration

Field with station range of named boundary

It would be great if we could create a field (text favorite) that would label the station begin and end of a named boundary for an index of sheets layout.