Calculation column in drainage and utilities flex table.
A formula could be made using existing columns to calculate a value that is atypical or not an option otherwise. I need a pipe full flow velocity check for a design. I can use excel to calculate using full flow capacity and full flow area but if t...
Allow Vertical Scale in Profile View to Stay Set after "Saved Settings" Or Change Default to 1
Currently, if you change the vertical scale in a profile view, it always reverts back to a vertical scale of 10 if you switch the view to display the profile of a different Line. It would be much better if the scale in the view would stay at whate...
Ability to update profile drawing model element annotation without removing full model annotation.
Currently, the software does not respond to removing element annotation in the profile drawing models. Instead, the entire model needs to have annotations removed, re-annotated, and then the individual elements need to be annotated.
IDOT's Right-of-Way annotation requires the Chord Bearing as part of the annotation. When setting up annotations for the Civil Labeler, we found that an option for the chord bearing is currently not available as a Text Favorite when selecting Civi...
In current version we do not have flexibility to change height/depth of a node from default 5.25 feet. At times we need lesser deep Nodes which does not require more than 1 or 2 feet of cover from soffit of conduit.
In PRT it was possible to snap a smart line to a specific chainage in plan by using the key-in 'SO=xxx'. In OpenRail the closest tool I can find is Civil Accudraw with station-offset toggled on, but I have found that often CivilAccudraw does not w...
There was a command in Geopak called Copy Chai
n Parallel that was very useful in creating offsets of survey chains, and creating new points at constant delta elevations. We are
looking for the same function to be added in OpenRoads Designer.
Clip Conduits (pipes) at inside edge of Drainage Structures and Report "True" Horizontal Lengths and Vertical Lengths in the Properties
This is more than useful; this is absolutely required. When laying out Drainage Networks, pipes need to be trimmed at the inside edge of the structures, and the "True" pipe lengths (horizontal & vertical) need to be provided in the properties....
I would like to see an improvement to the interoperability - Once you "Send To [LEAP]" the bridge model from OBM you are no longer able to modify the bridge in OBM and UPDATE the existing .lbcx file you are working in. I understand that significan...