Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Functional Areas

Showing 956

Point Control lock to to start and lock to end option should honor the corridor start and end limits

Actually , the lock to start and lock to end stations are defined by the start and end of alignment or feature the corridor it is based on. This makes the point control handles (in the 2d view) to be outside the corridor limits when the corridor i...
almost 2 years ago in Modeling / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Best Match Field Code Option

In ORD 10.11 and beyond the Best Match Field Code Option is now a drop-down of the following: Match exact: Feature Must equal an Alpha Code, only exact matches. For example if there is a Feature Definition with Alpha Code set to AP (Asphalt Paveme...
3 months ago in OpenRail Designer / OpenRoads Designer / OpenSite Designer / Survey 0 Future consideration

civil cell variables with expressions and variations

When we create parametric cells, we are able to use expressions to calculate values based on inputs, and in the properties of the cell, each of the variables (listed as visible) are shown, and you can adjust the cell from there. You can also creat...
over 1 year ago in Modeling / OpenRail Designer / OpenRoads Designer / OpenSite Designer 1 Future consideration

Make Grips Visible and Useable on 4k displays

When using Grips for Structures and Pipes - the grip blends too much into the background color, and on a 4K screen is TINY. The pipe grip is annoying to select (it only appears when I select the centerline of the pipe) but when adjusting or swapin...
10 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer / User Interface 1 Future consideration

Vertical Event Points

There use to be the ability to create Vertical Event Points. This appears to have been removed in that the Event Point List is now singular and tied to the Horizontal Alignment. The old capability (now removed) allowed things to be annotated in th...
about 2 years ago in Annotation 1 Future consideration

Retaining turnouts when horizontal alignments are dropped.

Currently when an alignment is dropped (no longer complex) all associated turnouts delete entirely and any geomtery created from these turnoiuts is also deleted. This is a big issue when optioneering, or when working on a scheme with lots of turno...
almost 2 years ago in Geometry / OpenRail Designer 2 Future consideration

The use of regression line/points to report lift information in profiles

Currently there is not functionality to annotated lift information using regression line/points. Have you use another design alignment (in this case it would the exisitng alignment). It would be great to be able to use one data source to report sl...
almost 2 years ago in OpenRoads Designer / Regression Analysis 0 Future consideration

Turn feature definitions on/off in a reference

If feature definitions are turned off in a file, it doesn't show up when reference and it's not possible to even view without going back into the file. It would be helpful to have the option to turn on feature defintions the same way levels can be...
almost 2 years ago in OpenRail Designer / User Interface 2 Future consideration

Openroads Drainage - HGL versus Headwater Analysis for Headwalls Inletting into a Storm Sewer System

Many times, a stream needs to be drained into a storm sewer system via a headwall. When this occurs, two analysis should be considered: The headwater at the headwall (the mechanics of the water getting into the pipe at the headwall). Generally KYT...
over 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

ORD Drainage - Show actual Tc versus Tc Minimum

Many times a calculated Time of Concentration is less than the minimum used for Intensity. When this occurs in a system of drainage areas (catchments), it helps a designer AND a reviewer to see what the actual Time of Concentration is at a given p...
over 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration