Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Functional Areas

Showing 1366

Add Corridor/Linear Template Vertical & Both Point Controls "Active Profile" option

Currently Corridor Vertical/Both Point Controls link the the specific Vertical Profile and when these get deleted, the Point Control is removed without warning. An option to set this point control to always use the Active Profile would allow this ...
almost 3 years ago in Modeling / OpenRail Designer / OpenRoads Designer 1 Future consideration

Re-associate turnout to an alignment

When you create a new alignment, break a alignment and lose the turnouts or import a geometry it would be good to be able to re-associate or change the alignment to which a turnout are associated/connected to.For instance when I´m working with a c...
over 2 years ago in OpenRail Designer / Turnouts/Crossings 1 Planned

Need ability to include General Project information in the IFC

This is the Feature Request to support the ability to include General Project information in the IFC. We would like to add several user-defined attributes to the IFC Site level, including "Organization Name", "Project Address", "Project Issue Date...
over 1 year ago in Import/Export / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Add ability to dual code survey points as one single point similar to InRoads Survey (add option to avoid overlapping annotation on dual coded points)

The biggest drawback to creating multiple points in ORD vs one single dual coded point in InRoads survey is overlapping text in annotation/labeling.
6 months ago in OpenRoads Designer / Survey 0 Future consideration

Land Use Areas from a Reference

It would be nice to extract Land Use Data from a reference file rather than requiring the Land Use Areas always be drawn in the main drainage design file. This would both cut down on clutter in the design file and also allow larger areas to be del...
over 2 years ago in Drainage and Utilities 1 Future consideration

Allow Annotation Groups to use "Place Text Along" from MicroStation

For a plan annotation group, the ability for annotation text on arcs/curves and spirals/transitions to be placed to follow the geometry centreline curvature. The present options only allow the text to be placed as a tangential/perpendicular straig...
about 2 years ago in Annotation / OpenRail Designer / OpenRoads Designer / OpenSite Designer 3 Future consideration

Visible final contour labels in corridor

After the corridor is created, it is possible to see the final contours. However, the contour elevation labels are not shown unless a proposed surface is created. Why is that so? I believe it would be beneficial to toggle on/off contour elevation ...
7 months ago in Modeling / OpenRail Designer / OpenRoads Designer 0 Future consideration

Bring back the “NE=” key-in command.

U.S. surveyors traditionally work in Northing & Easting, in that order. When working with Microstation V8i, AND with Inroads loaded, the user could perform precision drafting by using the “NE= “ key-in to enter the exact northing/easting coord...
over 2 years ago in OpenRail Designer / OpenRoads Designer / OpenSite Designer / Survey 4 Future consideration

Cross reference plan and profile sheet number annotation form Sheet Index

Add ability to cross reference the sheet numbers of plans that are in the sheet index. IE: referencing the profile sheet number on the plan sheet and vice versa.
over 2 years ago in Annotation / OpenRail Designer / OpenRoads Designer / OpenSite Designer / User Interface 0 Future consideration

Annotation : Annotation be added to display the degree of curve in chord definition

In a previous update, the plan annotation option to display arc length in chord or arc definition was added. It is imperative that a plan annotation be added to display the degree of curve in chord or arc definition as well. Until this happens we ...
about 1 month ago in Drawing Production / OpenRail Designer / OpenRoads Designer 0 Future consideration