Currently the Node-Connect Pipe Flex Table can report -Pipe- Label, Description, Rise, Inverts (Start & Stop), and Size. It would be useful if the angle of each pipe could also be included. Often in design need to verify a minimum distance bet...
Retain Observations When Skipping Duplicate Points During Survey Import
During survey traverse workflows that span multiple days, users must import several raw data files into a single field book. Often, points established on a previous day are re-observed as backsights on subsequent days. Currently, the conflict reso...
Currently, Drainage and Utilities feature definitions get captured via the CIVIL_CONTENTMANAGEMENTDGNLIBLIST variable within the workspace. Many configurations often use wildcards and file names that lump together features of D&U with road, ra...
Use machine threads to run several influence lines from the same surface in parallel
Situation Description
RM Bridge large model requires several days to complete execution when running vehicle influence line results.
The current workflow for influence line calculation appears to be sequential, resulting in excessive computation t...
It would be nice to be able to export a drainage network into 2D linework that can be edited for plan sheets. Currently, we don't use our modeled files directly in our plan sheets as we cannot adjust the conduit line styles and it takes longer to ...
Bulk updating of hydraulic grade line across multiple profiles and scenarios
Introduce a tool that allows users to update Hydraulic Grade Lines (HGLs) across all profiles simultaneously for multiple storm scenarios. Currently, when we want to display 3 storm events at once, we have to run it as a batch or child scenario an...
An option to add line style scale in the Display Rule. We have a customized line style for our Storm Conduits. We scale them in the element templates according to size of the pipe. (also an idea, option to use element template for the Display Rule).
It would be good to be able to annotate elevation of vertical regression line. But today the elevation is not available information when creating the text favorites.It requires additional step to annotate existing low rail elevation on profile: Us...
Include All Nodes in the HEC-22 and AASHTO Detailed Reports
When I run a scenario and open the HEC-22 (Third Edition) Detailed Report or AASHTO Detailed Report, I don't see the most upstream node and the most downstream node of a storm sewer pipe run. One issue is the reports are based on conduits. Try mak...
Allow users to add additional nodes to a drainage area after it has already been placed using the place catchment feature. This would eliminate the need to recreate drainage areas when updates are required.