Annotation Group Definition Copied to Active File when Used
When labeling civil geometry (alignments for example), whichever annotation group that is utilized is copied from the DNGLIB and saved with the active DGN. This is only the case when the geometry being annotated is stored within the active DGN, no...
The prompt for compressing the drainage database needs some work: It really should be removed. Salvaging anything marked for deletion but not compressed isn't really feasible in OpenRoads environment. Do not prompt me twice. It should be assumed t...
ORD SUDA - Single gradient property - False for stormwater and wastewater conduit
Hi, We were wondering if it would be possible to change the single gradient property function for stormwater and wastewater conduit.
"Single Gradient - This is always set to true for storm and sanitary conduits. For other types of conduit, it i...
For steel beams- When we create stiffeners and use them in cross frame definition, regardless of the method used, the stiffener tables when opened default to the first stiffener in the OBM library rather than the stiffener used in cross frame definition
Currently when we create a new stiffener and then when we create cross frames using those stiffeners, they don't show up when you open stiffener definition after creating cross frames (the first stiffener definition within the selection is shown)
It would be very helpful if there was a way to simply Add a Conduit to an existing Profile Run. For example, I have a storm network modeled and a bunch of drawings created by using a Profile Run, but now I needed to add another conduit at the end ...
Export pier or abutment templates to Functional Component
Often times a small edit is needed to make an existing abutment or pier template match project standards. It is tedious to create a Functional Component from scratch for small edits. It would be helpful to have a tool or button to export a templat...
Annotation group for elevation, offset and point name
We need to annotate point name, offset and elevations in cross sections for rail Earlier it was being done in power rail using preferences. The drawing model scale annotation is 1:30. I tried adding point annotation using text favorite from civil ...
For the modeling and model review process, it would be helpful to have Description fields for common corridor inputs, such as Parametric Constraints, Point Controls, etc. that can be easily discovered using the Corridor Objects tool.
Rm Bridge: Use local axis for leading envelope displacements when local axis results are being reported
When reporting envelope .sup files, the leading value when reporting displacements is always global, while the results displayed are either local or gobal (selected by the user). This is inconvenient for displacement envelope result reporting when...
Text Favorite cross section slope - hide trailing zeros
We are able to format most text favorites to hide trailing zeros. However, we are not able to hide trailing zeros for text favorites for Cross Section Annotations > Segments > Slope. We can define the precision, but there is no option to hid...