Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

OpenBridge Designer

Showing 117

ORD Design File Settings>Working Unite>Resolution change tool

Is there a tool in ORD that can change the Design File Settings>Working Unite>Resolution and scale the model so that the model remains at the correct scale after the resolution change. Is there such a tool? If not, that is my design enhancem...

MS_LEVEL_DO_NOT_OVERRIDE_DESIGN_LEVELS_IN_DRAWING

Please add a variable MS_LEVEL_DO_NOT_OVERRIDE_DESIGN_LEVELS_IN_DRAWING that does what MS_LEVEL_DO_NOT_OVERRIDE_DESIGN_LEVELS_IN_SHEET does for sheets but for drawings

Add support for buildingSMART IDS

IDS as Information Delivery Specification is a standard comes from buildingSMART which ensure openBIM pricipes for exchange of information requirements and validation. Please check at https://www.buildingsmart.org/what-is-information-delivery-spec...

Frame action or double curvature to be considered when superstructure is integral with substructure

When a superstructure is integral to substructure for Leap Concrete, both girders in the superstructure module and columns in the substructure module analysis/ design should incorporate frame action for any design load cases such as breaking force...
10 months ago in OpenBridge Designer 0 Future consideration

Option to Edit the Loads Font on Leap Conc -> Sub -> Geo Tab

I would like the option to edit the font on the Leap Concrete, Substructure tab, Geometry Tab. This way the text displayed that shows the loads can be increased which can help when saving images for review and record keeping. Thanks
over 1 year ago in OpenBridge Designer 0 Future consideration

Add Additional Check points to Wall Piers

Be able to add additional check points in the Str. Model Button for Wall Piers. Currently it is not applicable for these piers
over 1 year ago in OpenBridge Designer 0 Future consideration

Add a negative function into longitudinal/transverse offsets

Greater flexibility for wingwall placement
over 2 years ago in Geometry / OpenBridge Designer / OpenBridge Modeler 0 Future consideration

Design Footing with sides that are parallel to the column sides

Some tight geometric conditions require a this scenario
over 1 year ago in OpenBridge Designer 0 Future consideration

Place one bearing at pier location for continuous span concrete girder bridge design

Ability to place only one bearing at pier location for continuous span concrete girder bridge design, two girders shearing one bearing at pier location.
over 2 years ago in OpenBridge Designer / OpenBridge Modeler 0 Future consideration

Separate geometric ratios summary from stress ratio summary

OpenBridge LEAP Steel Summaries include geometric ratios (like 6.10.7.3-1) together with stress ratios. This is not helpful, as that ratios is not a real demand/capacity ratio, therefore when that geometric value of "performance ratio" is high, it...
11 months ago in OpenBridge Designer / Reports 0 Future consideration