at the moment, in Open Rail CE 2022 Release 1, we can edit speed in cant editor . it is not comfortable to have two windows (speed table and cant editor) when we design cant, speed. better solution to have it in one window
DU conduits external wall controled by Feature Symbology
We have the option to define a template to pipes external walls, but only through the feature definition. For all other elements of the pipe, OR allows for feature symbology. From my experience, symbologys work better and are more constant.
We have the ability to create multiple profiles from multiple surfaces at the same time, but there are occasions where I only need to define a single profile line based on multiple surfaces. It would be handy if there was an option to create a pro...
Create Top and Bottom Meshes for Surface Templates
Currently ORD will create a top mesh and bottom mesh when a template is assigned to a corridor. However, when a template is assigned to a design non-corridor terrain, no top or bottom meshes are created. Doing so would be very useful for viewing o...
Annotation Group Definition Copied to Active File when Used
When labeling civil geometry (alignments for example), whichever annotation group that is utilized is copied from the DNGLIB and saved with the active DGN. This is only the case when the geometry being annotated is stored within the active DGN, no...
The prompt for compressing the drainage database needs some work: It really should be removed. Salvaging anything marked for deletion but not compressed isn't really feasible in OpenRoads environment. Do not prompt me twice. It should be assumed t...
ORD SUDA - Single gradient property - False for stormwater and wastewater conduit
Hi, We were wondering if it would be possible to change the single gradient property function for stormwater and wastewater conduit.
"Single Gradient - This is always set to true for storm and sanitary conduits. For other types of conduit, it i...
Sorting and Grouping of Corridors and Linear Templates
Currently Corridors and Linear Templates are very poorly sorted in Explorer. These need to at least be sorted alphabetically to allow users to easily find the Corridor/Linear template they are looking for. Our major projects have dozens and dozens...
about 3 years ago
in Modeling
0
Future consideration
Don't process corridor for change of disabled Point Control or Parametric Constraint
Not sure why it does this, but it doesnt make sense that the software processes when these are changed although they are disabled. To aid in productivity, especially for large corridors, the corridor should check if the Point Control / Parametric ...