Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

OpenRoads Designer

Showing 955

Circular Eccentric Nodes should have the ability to have a rotation point at the center of the structure.

Circular eccentric nodes, like manholes, should have the ability to have a rotation point at the center of the structure and elevation reference at the center of the frame and cover.
over 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Option to overwrite Saved views when reprocessing named boundaries to sheets

Allow a checkbox to choose to overwrite or replace existing saved views when re-processing a set of named boundaries for output to sheets. This will help to maintain order in the files and avoid excess unused items. If not creating another 'versio...
over 1 year ago in Drawing Production / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Allow Design Scenarios to change proposed conduit properties and class based on depth of conduit.

The class of a pipe is primarily selected by the depth of cover over a pipe. Sometimes vehicle loads or construction loads have an influence on the class selection
over 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 1 Future consideration

Provide a list of Outdated Cached References

If a drainage profile uses a cached view rather than a dynamic one, ORD will provide a notification in the bottom right-hand corner that simply says "Cached References are currently displayed. One or more cached references does not match the curre...
almost 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

"Curve Set" text favorite annotation should annotate entire curve set

Under the Curve Set option under Location, an option for Spiral Left Middle, Spiral Right Middle, Curve Left Middle, Curve Right Middle needs to be added. Ability to annotate the Middle of a Spiral and/or Curve within a Curve Set. These options ne...
almost 3 years ago in Annotation / OpenRail Designer / OpenRoads Designer / OpenSite Designer 1 Future consideration

Update GUI for Editing Template Transitions

I find the interface for editing template transitions archaic and difficult to understand for new users. Is this something already in the works for development?
over 1 year ago in Modeling / OpenRail Designer / OpenRoads Designer / OpenSite Designer / User Interface 0 Future consideration

Annotation Group Definition Copied to Active File when Used

When labeling civil geometry (alignments for example), whichever annotation group that is utilized is copied from the DNGLIB and saved with the active DGN. This is only the case when the geometry being annotated is stored within the active DGN, no...
3 months ago in Drawing Production / OpenRail Designer / OpenRoads Designer / Workspace 0 Future consideration

Issues with Drainage Prompt to compress database

The prompt for compressing the drainage database needs some work: It really should be removed. Salvaging anything marked for deletion but not compressed isn't really feasible in OpenRoads environment. Do not prompt me twice. It should be assumed t...
3 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer 1 Future consideration

ORD SUDA - Single gradient property - False for stormwater and wastewater conduit

Hi, We were wondering if it would be possible to change the single gradient property function for stormwater and wastewater conduit. "Single Gradient - This is always set to true for storm and sanitary conduits. For other types of conduit, it i...
3 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer 2 Future consideration

ORD DU File Recovery Tools

ORD DU File recovery tools would be extremely handy when dealing with support issues. I've had to deal with a support ticket where the file is crashing upon opening several times now, and being able to run some tools outside of ORD would be extrem...
over 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 3 Future consideration