Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Applications

Showing 1527

Create corridor without vertical

Having the ability to create a corridor without needing a vertical can be helpful when a project involves widening. With widening, I wouldn't need a profile along the CL, but instead it would be along the EOP. Point controls can be used to attach ...
about 2 years ago in Modeling / OpenRail Designer / OpenRoads Designer 0 Future consideration

Incorrect arc radius for turnout outer curve switch.

For turnout annotation, we need to add turnout with LLS Extension from the library. I know that it is possible to add LLS radius value for a defined curved turnout in the library, but for a complex project where there are a lot of curved turnouts ...
about 1 year ago in OpenRail Designer / Turnouts/Crossings 0

No subtraction of sleepers from ballast in corridor report

Corridor report does not subtract the volume of sleepers we added to the model from the ballast. I propose to add in the next version of ORD the possibility to subtract in the ballast the added sleepers.
about 1 year ago in OpenRail Designer / Reports 0 Future consideration

No possibility to set the lower limit height of the profile

When creating profiles using ,,Named Boundary”, I cannot set the lower height limit of the profile. I propose to add in the next part of ORD setting the lower height limit if we want to make one drawing sheet from profile. This would help with the...
about 1 year ago in Drawing Production / OpenRail Designer 1 Already exists

Frame action or double curvature to be considered when superstructure is integral with substructure

When a superstructure is integral to substructure for Leap Concrete, both girders in the superstructure module and columns in the substructure module analysis/ design should incorporate frame action for any design load cases such as breaking force...
about 1 year ago in OpenBridge Designer 0 Future consideration

Ability to customized terrain check report with RMSE values and confidence percent in a excel out put.

This would be extremely helpful in final deliveries to clients reports, providing them with statistice they need.
about 2 years ago in OpenRail Designer / Terrain 0 Future consideration

Adding Japanese Cubic Parabola

OpenRail Designer seems to have Japanese Sine spiral type added from the formula used in Power RailTrack. However, there seems to be nothing similar to Japanese Cubic Parabola, which is based on a different formula from Japanese Sine.
about 1 year ago in Geometry / OpenRoads Designer 0 Future consideration

Update "Coordinate Grid" tool to allow more options

The "Coordinate Grid" tool needs to be updated to provide more options of the coordinate text placement allowing offsets & rotation etc. There should be, at a minimum, the same amount of control as we had with the InRoads tool "Place Coordinat...
about 2 years ago in Annotation / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

The ability to set a corridor feature definition that automatically increases the template drop interval in sections with curvature and superelevation

As we transition to using the model as a legal document, we are refining the standards we have for template drops to ensure our model provides adequate information to be used directly in construction. Our standards will require a certain interval ...
about 1 year ago in OpenRoads Designer 1 Needs review

Provide Low Point/High Point Information in Profile Table Editor

Lost functionality that was available in Geopak. Helpful to meet specific locations when designing a profile, instead of storing the profile and reading the profile report, or hand calculation of the low and high points.
about 1 year ago in OpenRail Designer / OpenRoads Designer / User Interface 0 Future consideration