Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Applications

Showing 1263 of 1410

GenerativeComponents - Alignment Node

Special Node/Option for Full recognition/utilisation of Alignment in GenerativeComponents. Since GC made it's entry into Civil products, it is vital that it gets tools (Node/-s) vital for closer cooperation with Civil Packages who make us of Align...
about 1 year ago in Geometry / Modeling / OpenBridge Modeler / OpenRail Designer / OpenRoads Designer / OpenTunnel Designer 0 Future consideration

Allow Plan Annotation>Arc>“Arc Length” property to annotate length for both Arc and Chord Definition curves so that only one text favorite is necessary to annotate curve length if both types of definitions exist in the same alignment.

With this issue we need to be able to create a single Alignment Feature Definition that will be able to annotate both Arc and Chord defined Curves in the same alignment. That single Alignment Feature Definition will have a Length Label “L” and it ...
almost 2 years ago in Annotation / OpenRail Designer / OpenRoads Designer 0 Planned

ORD DU File Recovery Tools

ORD DU File recovery tools would be extremely handy when dealing with support issues. I've had to deal with a support ticket where the file is crashing upon opening several times now, and being able to run some tools outside of ORD would be extrem...
10 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 2 Future consideration

Civil Labeler - Add ability to use in Sheet Model

Please add the option to use Civil Labeler in sheet models. For some sheets, there is no readily-apparent need to create a drawing model (e.g. for schematic-type drawings with no dimensions), so we only create a sheet model. Unfortunately, this pr...
over 1 year ago in Drawing Production / OpenRail Designer / OpenRoads Designer / OpenSite Designer 4 Future consideration

Add ON/OFF toggle option to Civil Labeler for Arrow Head

Just like you already have the option to toggle on and off a Box Frame or Text Divider around a label and the option to have a leader line or not, we would find it very useful to have the option to toggle ON/OFF an arrowhead.
almost 2 years ago in Drawing Production / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Ability to modify 'Rational Method Frequency Adjustment Factor' for a specific catchment or range of catchments.

Currently there is only an option to add Rational Method Frequency Adjustment Factors for the entire storm, which affects all catchments. Our GDOT standards require modification of the factor for only C values less than 0.6.
about 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Local edits to a template, now out of sync with library.

It would be nice to see what local changes were made, to a template, before Sync'ing to library. It currently notifies user that there changes made, but doesn't show what those changes are. It is difficult to know what changes may have been made t...
3 months ago in Modeling / OpenRail Designer / OpenRoads Designer / OpenSite Designer / User Interface 0 Future consideration

ORD Drainage - Separate CUlverts and Storm Sewer Pipes into Completely Separate Design Windows

Having to click 'Is Culvert' is just one more placve an error can take place in design. Creating spearate design windows for each of these elements will minimize this potential, and will make it easier for reviews as well.
over 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

ORD can't move new workflow to first

MicroStation can move a new workflow on first. But ORD can't move a new workflow on first.
over 1 year ago in OpenRoads Designer 0 Future consideration

Automate the assignment of a node's sump offset based on largest connecting pipe's wall thickness

We are looking for a workflow where the Sump depth value can be set to the thickness of the "largest pipe" connected to a node. When the user places a node, if there is an option to set the sump depth to the thickness of the pipe, then it would au...
10 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Needs review