Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Drainage and Utilities

Node-Connected Pipe Flex Table - Pipe Angle

Currently the Node-Connect Pipe Flex Table can report -Pipe- Label, Description, Rise, Inverts (Start & Stop), and Size. It would be useful if the angle of each pipe could also be included. Often in design need to verify a minimum distance bet...
about 15 hours ago in Drainage and Utilities / OpenRoads Designer 0 Needs review

Export Drainage Model to 2D Linework

It would be nice to be able to export a drainage network into 2D linework that can be edited for plan sheets. Currently, we don't use our modeled files directly in our plan sheets as we cannot adjust the conduit line styles and it takes longer to ...
over 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 3 Needs review

Bulk updating of hydraulic grade line across multiple profiles and scenarios

Introduce a tool that allows users to update Hydraulic Grade Lines (HGLs) across all profiles simultaneously for multiple storm scenarios. Currently, when we want to display 3 storm events at once, we have to run it as a batch or child scenario an...
3 months ago in Drainage and Utilities / OpenRoads Designer 0 Needs review

Display Rule (Display Style)

An option to add line style scale in the Display Rule. We have a customized line style for our Storm Conduits. We scale them in the element templates according to size of the pipe. (also an idea, option to use element template for the Display Rule).
8 months ago in Drainage and Utilities 0 Needs review

Include All Nodes in the HEC-22 and AASHTO Detailed Reports

When I run a scenario and open the HEC-22 (Third Edition) Detailed Report or AASHTO Detailed Report, I don't see the most upstream node and the most downstream node of a storm sewer pipe run. One issue is the reports are based on conduits. Try mak...
3 months ago in Drainage and Utilities / OpenRoads Designer 0 Needs review

Add nodes to existing drainage areas

Allow users to add additional nodes to a drainage area after it has already been placed using the place catchment feature. This would eliminate the need to recreate drainage areas when updates are required.
3 months ago in Drainage and Utilities / OpenRoads Designer 0 Needs review

Flex Table - option to be placed plan.

There are times we create a flex table so we can add as table on our plans. Currently several steps to make it happen. (export to csv, then import the table using excel/csv) There should be a direct option/button to add/place from the flex table t...
over 1 year ago in Drainage and Utilities 2 Needs review

Ability to Place a Conduit/Pipe "Without" a Node

Many times, we have conduits/pipes that simply daylight a surface and drain on to the ground or into a pond. Please add the ability to place conduit/pipes "Without" the need of a Node. I understand that we can create a sort of null point/node that...
almost 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Needs review

3d drainage node cut use baseline offset automatically

a lot of stormsewer profiles are run along our mainline vertical for plan illustration purposes. it would be beneficial if we had a special 3d cut mode that just read off the drainage properties of the nodes to create offset cuts even set them to ...
2 months ago in Drainage and Utilities / OpenRoads Designer 0 Needs review

Automated Catchment vs Alignment Low-Point Detection

Requirement:The system shall provide the ability to identify the low point at the intersection of a catchment area and the design alignment. This functionality shall assist the user in determining where a culvert is required. Process: Reference ...
2 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer 0 Needs review